Saturday, May 11, 2013

Technical Information


Products 80 Kg / m2 snow load, 90 km / h wind speed, and 3 1.Degree earthquake conditions Are being produced based on the climate zone.

1 - EXTERNAL AND INTERNAL WALL PANELS:
A-Walls 8X1250X2500 mm size, double-sided cement board. .
B-rigid polystyrene foam between two plates pressed load-carrying capability is provided.
C-40 mm thick polystyrene rigid foam used for thermal insulation.
D-heat conduction coefficient K: 0.64 kcal/m2 hc.

2 - WALL COMPOSITION:
GALVANIZED join sheet metal bending elements are combined with special clamping system.
Sweating occurs as a result will not rust radius edges.

3 - Doors:
A-Exterior doors steel joinery and measures 80 X 200 cm.
B-80x200 ölçülerindedir.İç Interior doors MDF doors, double-sided pressure-plated metal frame and wings.
C-external doors, interior doors, mortise lock cylinder will be installed.



4 - Windows:
A-Special-shaped PVC and measures 100 X 120.
B-Transom PVC and measures 40 X 60.
C-4 +9 +4 mm thermal glass windows.


5 - STEEL STRUCTURE:
A-box profiles and galvanized steel roof truss manufacture special profile of the produced wood with Columns
purlins in the steel frame acts as a carrier. Throughout the building every 125 cm has a steel spring.
B-Lovers 5 * 5C cm wood.


6 - CEILING AND INSULATION:
A-ceiling coating, 12 mm thick gypsum plates
B-80 mm thick glass wool insulation of the ceiling provided.
The combination of C-Ceiling suspended ceiling under the roof girders welded edges omegalarına form verilir.Sacın
sweating occurs as a result radius corrosion does not occur.
D-drywall joint elements are made of powder coated aluminum.
E-ceiling heat conduction coefficient K: 12:49 kcal/m2 hc.


7 - ROOF COVERING:
A-Wood Lovers on the Trapeze 0.50mm Galvanized steel, coated Shingle Ondilin or optional.
B-building around the eaves bent from sheet metal are 20 cm wide GALVANİZ.
C-profile material with seismic diagonal roof.
D-fitted PVC rain gutters and down.


8 - PAINT:
A-double layer coating the external metal surfaces, dual-layer synthetic painted with oil paint.
B-External fiber cement board painted with acrylic exterior paint.
C-painted with plastic paint on interior walls and ceilings.
Outer walls are coated with mastic joints.


9 - ELECTRICAL INSTALLATION:
A-All the installation of TSE standard PVC cable installed externally.
B-Switches and Sockets VİKO brand.
C-lighting luminaire PELSAN TMS. (There is no electrical panel and meter.)


10 - Plumbing:
A-The clean white pipes are PVC plumbing.
B-Waste PVC plumbing pipe.
C-Fittings and accessories TSE certificated.
E-Waste and clean water supplies outside of the building is up to 1 m.
E-water counter is installed by the customer.


11 - story construction: (for 2 storey buildings)
Profile as carrier cage construction is A-Half.
16mm.taşıyıcı middle-flat cage on the fiber cement board (cement-bonded particle board) is covered.
C-in sound insulation on the suspended ceiling is covered with 80mm thick glass wool.
The carrying capacity is calculated as D-Half 200kg/m2.


12 - STAIRS (2 storey buildings)
A-box profiles obtained from the concrete slab on steel frame covered with 16mm thickness.
B-double coat of primer and two coats skeleton part of ladder shall be painted with oil paint.
Stair railing will be C-box shaped profile.